……QC5200 Handheld Computer User’s Guide
8 Introduction to Windows CE The QC5200 Handheld Computer is powered by Microsoft® Windows® CE, an operating system designed for mob
9 Command Bar Use the command bar (also referred to as the taskbar) at the bottom of the screen to perform tasks within applications. The
10 Control Panel The Windows CE Control Panel can be used to configure and customize the settings of the QC5200 Handheld Computer.
11 About Your QC5200 Handheld This section will introduce some of the basic components of the QC5200 Handheld Computer, including its display,
12 Touch Screen Figure 5 - Touch Screen Calibration Use the touch screen to enter information into the device. If the device is not responding pr
13 Display The QC5200 Handheld Computer contains a 3.5” LCD display with a resolution of 240 x 320 pixels. The device is a color LCD. Th
14 Speaker Figure 7 – Volume & Sounds Properties The QC5200 Handheld Computer includes a front-facing speaker with a sound pressure
15 Flash Memory The QC5200 Handheld Computer contains 256 MB of Flash memory. Part of Flash memory contains the Windows CE Ope
16 Keypad Figure 9 – Keypad Layout Keypad Layout The QC5200 Handheld Computer features a keypad consisting of twenty keys, as shown i
17 The Power key can be used to generate shortcuts to various QC5200 Handheld Computer functions. These shortcuts are as follows: To
1 Copyright © 2010 Cummins Inc. All rights reserved. No part of this documentation may be reproduced or transmitted in any form or by any m
18 Hard Reset In cases where the internal RAM is corrupted to the point that the unit will not boot, it may be necessary to perform a Har
19 USB Connector Figure 11 – USB Cable The QC5200 Handheld Computer includes a proprietary cable for connecting it to a standard US
20 Battery Charging The QC5200 Handheld Computer contains a removable Lithium Ion soft-pack cell with built-in protection circuitry. It has
21 Installing QC5200 PC Software To install your QC5200 PC Software, please follow the instructions below: 1. Insert the QC5200 Application Su
22 Installing the USB Driver The appropriate USB driver from the companion CD must be installed on the PC. If the driver isn’t
23 Figure 14 - Select the Driver Dialog The Found New Hardware Wizard should detect the device as USB Sync. Click Have Disk. Browse to t
24 Transferring Files Figure 16 – Mobile Device The ActiveSync or Mobile Device Center icon in the PC’s system tray will turn green when a
25 Install and License PowerSpec PC POWERSPEC PC may be obtained from our website at www.powerspec.cummins.com. Once the POWERSPEC PC s
26 Introduction to PowerSpec CE The POWERSPEC CE application allows you to read and capture select engine and subsystem data from your diese
27 Current Screen This label is an indicator of which screen is currently being displayed: Trip Information, Fault Codes, Read Feat
1 DISCLAIMER POWERSPEC CE AND QUICKCHECK CE SOFTWARE, REFERRED TO HEREAFTER AS COVERED CODE, IS PROVIDED UNDER THIS LICENSE ON AN '
28 Exit Icon This icon is used to exit the POWERSPEC CE application. Tapping this icon will display the “Are you sure…”box shown in
29 Read/ Reset Faults The Fault screen's primary purpose is the display of diagnostic fault codes that are currently recorded o
30 Fault Description Dialog Box The list box on the Fault Screen shows all of the active or inactive faults that are recorded on the c
31 Read Feature Settings Select 'Read Feature Settings' to have POWERSPEC CE read your engine feature settings and display t
32 Edit Feature Settings A feature may be enabled or disabled by tapping the appropriate symbol and tapping the Apply button. Other parameters ma
33 Transfer HotSpec Option The Transfer HotSpec option is used in conjunction with POWERSPEC PC to transfer a HotSpec to the QC5200
34 Moving the HotSpec The HotSpec will be automatically copied from the desktop PC to the QC5200 handheld device. The HotSpec can then be tran
35 in the default 'Changes Only' mode, which means that it only shows feature settings that were changed during the transfer. If no par
36 Equipment Pull-Down The Equipment Pull-Down is used to classify records according to the vehicles they were extracted from. The
37 execution. This only changes the datalink selection for this session. This selection will not be saved once the POWERSPEC CE appli
2 Table of Contents Caution... 5 Welcome ...
38 About Screen The About screen displays information about the POWERSPEC CE software such as the current version and build date. It a
39 POWERSPEC CE Basic Tutorial This section describes a typical data-gathering session. It begins with collecting (scanning) the data, saving
40 distance must be greater than one mile to create a trip report. Next choose Fault Codes by tapping the Fault Code or pressin
41 Installation The installation of the POWERSPEC CE is described in the QC5200 Installation of PC software section. Data The conduit tra
42 Introduction to QUICKCHECK CE The QUICKCHECK CE application, in conjunction with the QC CONFIGURATOR program, allows you to read and captu
43 Current Screen This label is an indicator of the currently active screen: Equipment, Fault, Monitor, or Trip. It changes as the Navig
44 of the screen. Equipment information uniquely identifies a vehicle and can be used to distinguish one set of data from anoth
45 for a new vehicle so that it can be retrieved in future connections. Zoom Box Some data plate fields may contain strings of informa
46 area of the screen. When using QUICKCHECK CE, glance at this portion of the screen for an idea of the current overall status
47 Faults Subsystem Selection Tapping the Fault Subsystem will expand to show all of the available subsystems from which faults may be read.
3 Formats ... 41 Introduction to QUICKCHECK CE ...
48 key while the selected row is highlighted. When a fault code is selected, the Fault Description dialog box is opened. The Fault Description
49 subsystem model, some SAE parameters may not be supported on your vehicle. These may show up as random character values or as ‘U
50 Review Mode Review mode is used to view data records that have been stored on the handheld unit. For the QUICKCHECK CE applic
51 Record Pull-Down The Record Pull-Down will show all records saved for that vehicle. Remember that, once ActiveSync’ed, these records a
52 from the equipment list and will delete all data records associated with that piece of equipment. Once erased, these records
53 QUICKCHECK CE Basic Tutorial This section describes a typical data-gathering session. It begins with collecting (scanning) the data, savin
54 name or label that is logical, user friendly, and easy to remember. You should still be looking at the Equipment screen where t
55 At this time, select the File->Save Data Record menu item. Doing this will initiate the data-saving mechanism of QUICKCHECK
56 QC CONFIGURATOR The QC CONFIGURATOR is launched from the QUICKCHECK CE menu. The Display screen contains several screen objects,
57 parameter, as described later. Note that a maximum of 35 QC Configurator parameters can be configured to be displayed on the
4 POWERSPEC CE Installation Problems... 75 POWERSPEC CE Hardware Problems...
58 Menu Options The drop-down menu contains several options, each pointed out in the pictures below and described in the paragraphs that f
59 Save List As This menu item saves the current configuration with a different file name. Delete This menu item removes a configuration from
60 Parameter Identifier Description Screen In order to view the Parameter Identifier (PID) Description screen, tap the row of the des
61 Subsystem List This pop-up contains subsystems with parameters that may be broadcast3. In order to change the subsystem source of a para
62 QC CONFIGURATOR Basic Tutorial This section describes a typical configuration session. It begins with creating a configuration, setting t
63 SyncReports Cummins SyncReports is the PC application that is handling synchronization between the PC and the QC5200 handheld device. It is auto
64 Tips: - Click Show More Details to view a detailed report of the synchronization process. - Click File -> Save Synchronization Result to
65 Location The location of the SyncReports output files is as follows: C:\Documents and Settings\All Users\Application Data\Cummins\Common\QuickC
66 <FAULT> <FAULTID>94</FAULTID> <FMI>4</FMI> <MID>0</MID> <FAULTCOUNT>2</FAULTCOUNT> <FLA
67 Faults Information Tag Name Description FAULTCOUNT Number – number of occurrences of fault FLAGS 0x02 set if fault active (cleared if inactive)
5 Caution • Do not attempt to service the QC5200 Handheld yourself. Do not disassemble, modify, drop, puncture, mutilate, solder, or alte
68 Hardware Processor: Intel PXA270, 416 MHz RAM: 64 MB SDRAM Flash: 256 MB NAND Flash Display: 3.5, STN, 320x240, Color TFT LCD Battery The Q
69 • Any electronic systems on the vehicle (for example ABS)
70 Warranty Products Warranted This warranty applies to New QC5200 Handheld Computers, sold by Cummins Inc. (hereinafter ‘Cummins’) and
71 Return Policy All returned merchandise must be in saleable condition with manufacture’s original packaging. Cummins Inc. and its
72 Appendix A: Maintaining Your QC5200 Handheld Datalink Cable Storage The datalink end of the cable should be disconnected from the vehicl
73 Appendix B: Frequently Asked Questions Before contacting your local Cummins distributor for support, please experiment a bit to reproduc
74 To find ActiveSync Manager Version information: • Click the ActiveSync Manager icon in the Windows system tray on the bottom right side
75 I did an ActiveSync operation, but my PowerSpec CE data did not get uploaded to my computer. • Verify that the ActiveSync is ver
76 Cummins QC5200 Application Suite. I tried to install a new version of PowerSpec CE software and it would not install properly
77 organizer by an ActiveSync or by deleting unwanted records will speed up the application.
6 Welcome We thank you for purchasing a Cummins QC5200 Handheld Computer for Automotive and Industrial vehicle and diesel engine a
78 QUICKCHECK CE Installation Problems I’m having problems installing my Desktop organizer software. • Review the ActiveSync Problems secti
79 ActiveSync the device with the desktop PC. • Uninstall the older version of software from the desktop PC. Select Control Panel,
80 Data from equipment cannot be saved without an Electronic Dataplate that includes the make, model, and serial number. I went into Rev
81 Appendix C: Fault Codes This section provides information about the engine and vehicle subsystem fault codes that you may receive fr
82 SAE J1587* and J1939 Failure Mode Identifiers (FMI)** FMI Description 0 Data valid but above normal operational range 1 Data valid but belo
83 ** - FMI descriptions always follow the PID, SPN, or SID descriptions in the detailed Fault Description zoom box. Appendix D: Glossary Accel Pe
84 Intake Manifold the temperature of pre-combustion air supplied to the intake manifold (in degrees Fahrenheit or degrees Celsius) J1587 a low-s
85 Total PTO Hrs accumulated time of operation of the power takeoff device (in hours) Total Veh Dist accumulated distance traveled by the vehicle
86 Appendix E: Connector Pin-outs Cable 3165160 DEUTSCH HD16 - 6 - 12S 6-position connector A - J1587 + B - J1587 - C - Power + D - NC E - Gro
87 A 23 Ground B 25 Power + Technical Support 1-800-433-9341 © 2010 Cummins , Inc.
7 Introduction to QC5200 Handheld When you first power on the Cummins QC5200 Handheld Computer, the QC5200 User Interface screen will be l